foreign so we're going to discuss this iconic Vault temperature today why it has its shape and the sort of science behind um voltametry and particularly the shape this kind of duckbill shape that people sort of describe a voltamagram as looking like if you like the video please like and be delighted if you also subscribe and if you have any questions um do put them in the comments below if you're looking for more mathematical background or more examples or more in depth and please sort of leave that in the comments and we will address them so
the first thing we want to say is that voltametry is not just um a nice experiment to do in the lab it's actually something that does get used in the real world so one of these examples is one of the products that we have at zp which is really for measuring the hotness of chili but there's also other um for example medical products this is a product from a company called gemmark DX and they definitely use voltamber tree it's actually a ferrocene label in their medical product so for temperature it's not just an academic exercise
um it generally gets out there into the market and can make a real world impact now volatmetry does fit into these kind of you know group of electrochemical analytical techniques you have ampometry you have voltametry you have potentiometry you have an impedance spectroscopy now the ones become very powerful in the last few years that all these techniques can now be done let's say or powered by Electronics no bigger than your thumb or your the end of your finger I should say so let's history and electronic chemistry has become really powerful and it's really through thanks
to essentially men modern Electronics so thank you to the IC Developers for bringing us these great products now voltammatory there's lots and lots and lots of automatic techniques so even whenever I say linear sweet volatmetry lsv there's subdivisions within this you know there's anodic stripping for temperature it could be considered a form of linear sweet volatility but voltametry has lots and lots of types so we have linear sweep voltammatory cyclical temperature and it's really linear sweep and cyclical temperature that I'll cover today but there's also Square wave automatory if you want a video on Square
wave alternator please drop me a comment down below differential pulse photometry the same if you want to know more about that please leave a comment and the same for normal possible territory so there are lots of volumetric techniques and today we're just gonna really focus in on lsv and CV or cycle level territory so cyclical temperature as I say the first thing we're going to do is really explain this kind of iconic shape um it's one of those kind of symbols that you see throughout the world of electrochemistry you know various um manufacturers use it
in their logo you see on the front of books so we are really going to describe where this um shape of a tamogram actually comes from so um here we have the voltametry for ferrocyanide we're looking at the oxidation and reduction of ferrocyanides so on one axis here we have the current of the measured in um amps or amperes and we have the potential often measured in voltage people get very precious and that they sometimes say oh that's the voltage axis and then now people say it's a potential axis strictly speaking it's the potential access
and the potential is measured in volts but I don't get particularly precious about it but some people do um ferrocyanide is in the solution and ferrocyanide on the forward scanner we'll discuss that forward scan in a minute is getting oxidized to Ferry cyanide so fe2 plus has become fe3 plus and then we reverse the direction of the voltage we go in the and we go back again let's say and then um ferries cyanide fe3 plus that is is reduced to ferrocyanide fe2 Plus um now the waveform that generates this it's got a triangular waveform and
you'll soon sort of see why it's called a triangular waveform we have a voltage we start at some voltage so in this left-hand animation we start at minus 500 millivolts and we scan up to plus 500 millivolts and then from plus 500 millivolts we scan back to minus 500 millivolts we have a starting um position here a starting potential here we scan to here and then we go back again to the original point so that's a sort of triangular waveform so hiding behind every voltamigram there's a triangular waveform um linear sweep for temperature is really
similar except we don't go from one potential to the next potential and back again we just go from one potential to the next potential but we don't go back again otherwise there are pretty similar techniques the only reason I bring this in is that zp we are pretty fond of um screen printed electrodes we obviously manufacture our own we also manufacture and potential stats and then as I bring these two images in is because I really want modern Electro analytical chemistry to feel modern you know so you sometimes you do it and you know people
have glass vessels and electrodes and cables and I don't think modern analytical electrochemistry necessarily has to be that way you know when we do our science um maybe on our workshops Etc it's very clean you know in terms of and this is you know how modern electrical and chemistry or modern Electro analytical chemistry really should be presented I just threw in that um either just to say that ferrocyanide and and its oxidation to ferric Cyanide and the reversal of that is described as an e and mechanism you can have um ee mechanisms where you oxidize
it once and then you oxidize it twice that would be called ee sometimes you can have electrochemical followed by chemical that would be called EC sometimes you can have electric chemical followed by chemical followed by electrochemical and that would be called ECE that's not really what I'm going to dwell on today but I just want you to know that there are a whole bunch of EC ECE Prime all sorts of these arrangements and they really describe the kind of underlying mechanisms but the oxidation of ferrocyanide a fairy Cyanide and that reduction is a simple one
it's just called an e um mechanism so we're going to dive in a little bit deeper now and so you'll sort of say you know why does this look the way it looks um so we've got a sort of few color coding things going on here so the first part we're looking at here is we're applying a potential and we're applying that Potential from approximately minus um uh how can I describe this from approximately minus 500 millivolts to about minus 150 millivolts and we've got ferrocyanide in there but there's nothing happening and the reason that
nothing is happening is because the potential is not sufficient to cause the oxidation of the ferrocyanide to Ferry cyanide um now what happens next then is we hit a region and I would say this region is approximately minus 150 millivolts to about minus 50 millivolts and I think that's approximately right and in this region we can call it the kinetic region and what's happening is we are oxidizing the ferrocyanide to fairy cyanide so that is taking place um there's a little equation that describes this um this is the tafel equation I'm not going to derive
equations today and the only reason I put I mentioned the tefl equation is because obviously if you're trying to learn this subject there'll be certain equations that you'll be expected to kind of produce maybe in an exam or you know to sort of know about so I put the tefl equation in there this tefl equation describes this kinetic region and what it says is my current is proportional to my voltage but I am not consuming much um ferrocyanide and so I'm only under electron transfer limitations later on you'll see that once you start consuming ferrocyanide
you become what's called under mass transport control or specifically in a cycle of autometry often diffusion control diffusion is just a type of mass transport so we just went from a region where we had no oxidation of ferrocyanide now we're in this kinetic region just at this Foothill and we describe this as a kind of kinetic region um after that then we sort of hit a um a new region this is kind of the they call it is the faradayic um sort of region Faraday is you know there was a Michael Faraday um a very
eminent um chemist from you know several centuries back um one of the fathers of Modern Electric chemistry so when we have a chemical sorry I should say an electrochemical process people describe it as a faraday process or Faraday current you will also hear it's fine it just means that we're doing some electrochemistry where a chemical is giving up electrons to an electrode and that would be described as chemical you know an electrochemical that's a faradayic process now as we go from about minus 50 mL of minus 50 millivolts up past zero millivolts we're increasing the
voltage and all the time the current's going up and more and more Ferro cyanide is being converted to ferric cyanide but this can't go on forever because actually there's a point at which um we've consumed all the ferrocyanides at the electrodes surface and we hit this kind of peak so this peak comes about because we've been transitioning from the foot of the voltamagram where we were under kinetic control we started actually consuming the ferrous Cyanide and we consumed more and more of that ferrocyanate at the surface up until a point in which we actually essentially
depleted all of the ferrocyanide at the surface and we reached this peak and this peak is um described what can be described by the um Randall severic equation the Randall sevic equation kind of says that this peak height happens in a simple system to be proportional to the square root of scan rates and I will discuss that in a little bit so this at least first parts we have um a sort of background current because there's not sufficient potential then there is sufficient potential to oxidize the ferrous cyan how do we get the kinetic region
and the current starts just starts coming up a little bit then we hit this mixed region because what's happening is we're somewhat under kinetic control but now the ferrocyanide is being depleted and actually more need to diffuse in and so that's the mix because we're slightly under kinetic control and slightly under diffusion control then we hit this current exact this peak rather and this peak is really indicative though in fact all of the ferrous cyanide has now be consumed and now we hit this kind of transplant transport limited region where the current actually goes down
and the reason this current goes down is because the ferrocyanide is having to diffuse to the electrode from an increasingly increasing distance from that electrode and I have in a couple of minutes we'll be covering that in a bit more detail now there's a moment now where the um where the voltage actually reverses and then now what's happening is we've at the electrode surface all of the ferrocyanide has become ferrous um ferric Cyanide and now we started to try and do the reduction of fairy cyanide back to ferrocyanide but we're not providing enough voltage to
actually do all of that and but until we hit this kind of kinetic region at which point now we're in this kinetic region and actually the ferry cyanide is becoming ferrocyanide we add a bit more potential and we start actually converting some amount of that ferrocyanide into fairy cyanide so we're sort of reverse of what we were doing earlier on and again we hit a moment where we kind of back into this Randall sevic I'm not going to say equation the Randolph Civic equation characterizes it it doesn't drive it um where we don't get any
more current because in fact we consumed all of the ferric cyanide at the electrode and now we become transport limited um again so this kind of iconic shape is because we have how would I describe that at least about four different regions we have the background region the kinetic region the mixed region the Peak region and then that diffusion region so there's at least five sort of regions and then we reverse it all so that's why we have such an iconic shape because of actually the this is transitioned from with potential to these different essentially
regions um and the decent yeah we go from kinetic control to diffusion control um it's probably worth saying that um again you know if we if we look at this that we have that background region we have that mix control or mixed region which is described as the Faraday current again after that Michael Faraday and so we have two extremes here we have that kinetic region which was described as the tafel equation and where current is actually disproportional to the potential um and then we have a um an extreme where actually we hit the peak
current and that reason that Peak current comes about is because as we come up this mixed control region for example if we start with a solution of five millimolar Ferry cyanide we have five millimeter Ferry Cyanide and so the from the distance from the electrodes the ferrocyanide is all five millimolar but as we come up the mixed region the potential means that we consume some of that ferrocyanate and so it drops in concentration a bit and then we apply a bit more potential and the concentration of ferrocyanide drops a bit and then we apply a
bit more potential and the ferrocyanide drops a bit so what's happening is we we're increasing What's called the depletion layer the ferrocyanide is dropping in concentration at the surface and more ferrocyanide is having to diffuse in from the bulk up until the point where the ferrocyanide at the um electrode is actually zero and that's coincidental with that Peak there which as I say is described by the Randall sevic equation and the Randall cervic equation kind of says that current is proportional to the concentration it's also proportional to um V to the half U which is
the square of the scan rate and I will describe that again into more detail um in the next slide so we've been saying okay so cyclical temperature and linear Sweetwater temperature they're pretty much the same thing linear Sweetwater temperature you just go from V1 to V2 inside the photometry you go from V1 to V2 and back to V1 but as we change the voltage the um voltamagram is essentially generated at the same time so we have the um the scan here and here we have the resulting um voltamagram and then we have those regions of
background kinetic control sort of mixed control and we're under sort of Transport control um here so we have described that now there's a sort of um it's not necessarily in an intuitive parameter it actually says that the faster we go from V1 to V2 the higher the um Peak current and it's higher if it's a simple diffusional process like that of ferrocene or ferrocyanide it's the peak height is proportional to the square root of the scan rate and that's because it's under diffusion control and this comes from fixed law I'm going to describe this not
mathematically Brian describe this with models and animation so what I'm saying is the less time it takes to go from V1 to V2 the higher this peak current and I know that you know if you're following textbooks or you're doing lectures on this this is something that you're taught um but I'm going to try and actually explain it a bit more here um that Peak current is really driven by um the diffusion gradient near the electrode so this is the fairy cyanide concentration so um in the bulk it's five millimolar this is distance from electrode
and what it says is when I scan fast when you scan fast you go from V1 to V2 really quickly you hardly have any time to do any electrochemistry and so you hardly deplete the fe2 plus and convert it to fe2 plus when you go slowly you actually end up depleting fe2 plus and it becomes fe3 plus and so the diffusion gradient is shallower the slower you go and now with this gradient I'm going to explain to you in a minute this gradient's actually what drives the peak current so sharp gradients I.E those um of
fast scan rates actually give you higher Peak currents slow scan rates give you shallow gradients of concentration and they have lower Peak currents so fast and slow so if you go slowly you do consume fe2 plus you build up what's called the depletion layer this is the I say here diffusion layer but diffusion layer and depletion layer um and actually that gets bigger the longer or therefore the slower your scan rate if you do it fast this depletion is very small and so this gradient here is actually equal so that gradient is actually equal to
the concentration of the bulk five millimolar the concentration at the surface which is actually zero and I'm just going to um move myself out of the way slightly and just say that it's equal to the concentration divided by this diffusion layer so if the diffusion layer is large therefore you've scanned slowly this gradient is small and if the diffusion layer is um small I use scan very fast then that um that then that um denominator there makes that number actually quite big so Peak height is a reflection of these gradients and these gradients get steeper
the faster you scan and that's what's driving this link between the peak height and scan rate and the only reason I bring this up is that it's so kind of iconic or Central to you know at least when you're being taught electronic chemistry especially site level temperature this is what's driving um that and that's all wrapped up in the Randall severic equation as I say it's not something I want to necessarily derive and the reason I want to derive it is because I think it's better to qualitatively understand this before you and you can quantitatively
understand it's just an equation let's say it's quite a simple equation and once you understand what all the terms are um but knowing the equation doesn't necessarily give you an understanding of what's actually going on once you have an understanding of it you can see then where the terms are coming from in that equation and as I say current is proportional to the square root of a scan rate and I just want to finish with a kind of a last sort of slide on this which is the voltametry is considered very kind of iconic and
this psychopathometry is considered um iconic as well and I just want to say that the sort of shape that you're looking at it's really just a function the way you do the experiment if you did the experiment in a really similar fashion and you're actually rotating for example the electrodes you wouldn't get a um the cyclical temperature the way you're expecting you actually get it so for example if we rotate at 100 RPM so the same experiment except they now start to rotate I had actually get something that looks a bit like um the voltametry
we were looking at earlier on when it was just understood on the diffusion control but the more I stir then in fact you lose that essentially that Peak and you hit something that's more like a plateau so it sort of says to you that the only reason of all territory looks the way it looks the way it does one of the main reasons it looks the way it does is because it's in an understood solution and so as interesting as voltametry is and as iconic as that is it's really just all that CV is it's
just really a reflection of where the actual experiment is done once you start stirring then all of this kind of um depletion distance or the fusion distance goes away and um you have a new equation at this point by the way called the levage equation which says that the current is now proportional to the amount that you stir by so what I'm going to do now is I'm going to say thank you very much for following this video and I do want to invite you look any questions um please post them on in the comments
and I'll probably use those to generate the next videos in the series so thank you very much