this video will be an introduction to the basic concepts of cyclic voltammetry cyclic voltammetry is a commonly used electrochemical technique which in our case will be used to determine the concentration of acetaminophen in a children's pain relief elixir all right so what we have to understand here first is that we're going to be using an interest instrument called a potentiostat the potentiostat will be connected to the electrochemical cell which we will be constructing here in a few moments and the job of the potentiostat is to apply an appropriate potential or voltage to the electrode where the oxidation and reduction of the analyte of interest will take place now as a result of that oxidation reduction process a current will also flow at that electrode which becomes our analytical signal so the potentiostats other job is to measure that current flowing at that electrode where the oxidation and reduction of the analyte takes place all right so the first thing we would do is we would come in and we would turn on the potentiostat which i've already done here the next thing that we would do is we would make sure the potentiostat is in the external mode and that means now that the potentiostat will be awaiting instructions from the computer software that will then be controlling it and allowing for us to measure the current so we come over to the computer at this point to bring up the software the software is accessed through our shortcut to aftermath here which we can double click on which brings up our menu now there's no username or password required here so we're going to just say okay and that brings us into the main menu of the software so here to perform an experiment we'll see that we have a list of various experiments that we can access here cyclic voltammetry is the one that we want to look at today so we're going to double click there now to set up the experiment we have to actually set up the potential waveform that we're going to be applying to the electrode of interest so this is what our basic menu here will allow us to do so we're going to be placing some numbers into these fields here so to begin with we want to utilize three segments and i'll explain that here momentarily we need to have an initial potential so that's the voltage where we're going to start the experiment i'm going to set that at 0 volts i'm going to set our upper potential or positive most potential at 0. 8 volts this is somewhat arbitrary but i generally want to make sure that i'm getting out to a positive enough voltage that i can actually ensure oxidation of the acetaminophen the lower potential which will be our second segment will take us down to let's say minus 0. 3 volts i think that's what i want to put in all right and then our final potential is going to be 0 volts i want to initiate in a rising direction meaning that my first segment will be at 0 volts and i'm going to scan out 2.
8 volts so i'm increasing my voltage so i'm moving in the positive direction initially i'm going to keep the sweep rate which is the rate at which the voltage changes during each segment at 100 millivolts per second and now for the current range i prefer to actually manually go in and change that so i can go to auto and i can now change that to whatever range i want so i'm going to start with 5 microamps as a guess and again i can come back and change that as need be all right so at this point we're ready to run the experiment except that we need to set up the cell so when the time comes we'll come back and hit perform now at this point i'm going to come back around to the electrochemical cell itself now the cell of course is going to be in a container and the container right now holds the one molar buffered saline solution so we're going to run a cyclic voltammogram on that to determine what the background voltammetry is going to look like now to do this i have to set up the three electrodes in my three electrode cell the silver colored electrode that you see at the top is actually a platinum rod and that will be our counter or auxiliary electrode we'll also need a reference electrode that's the one that you see right here it sort of looks like glass and that's a silver silver chloride reference electrode and then finally the working electrode is the one at the bottom here and that as i'm going to show you momentarily is going to be a carbon disk electrode all right so a few things that we have to do to set up first i'm going to set up my tripod so that i can get both hands free here so i'm going to focus down on this region right here and what we need to do initially is we need to um actually clean the working electrode so you see here the working electrode now you might be able to see it here but there's a glassy carbon disk on the end i think you can see it right there now what happens is that organic matter will absorb to that carbon disk so what that means is that the electrode will be fouled so we need to clean the electrode now so that efficient electron transfer can take place there so essentially i have some sandpaper here that i've wetted down and i'm just going to grind the electrode along that sandpaper there to abrade off any material that may be absorbed to the electrode surface okay once that's done i can come back with a kimwipe and i can wipe down the surface of the electrode and take a look at it and it should be mirror polished at this point you probably can't see it but it has sort of a mirror polished finish to it okay so i know now that the electrode is clean now the next thing that i want to do is i want to set up the electrochemical cell so i'm going to now focus on the cell itself and i'm going to put the electrodes together into this little cell holder here okay so what we can do is come back around place the working electrode in there along with the auxiliary electrode we'll also pick up the reference electrode and place that in there as well and what i end up with is an assembly that looks something like this okay that whole assembly will be dipped into the cell container and as i mentioned before the cell container is filled to about two thirds or halfway point um with the buffer solution here okay so now you can come in here and see that all right now the next thing that we need to do is we need to actually make connections between the potentiostat and the electrochemical cell okay so we have three connectors here one's up here at the top and then two are down here and we can track those back to the electrode connections here on the potentiostat now the ce which is the red cable ce stands for counter electrode so i'm going to attach that in here to the platinum rod okay so you can see it attached to the platinum rod there now the black cable comes back to the k1 electrode which is the working electrode so the working electrode of course is going to be the um carbon fiber or rather the carbon um disc electrode here so i've actually brought my alligator clip in and hooked in to that and then the final electrode here is the silver silver chloride reference electrode so i'm going to come in and make my connection there to this final alligator clip here and i'll show you momentarily what the whole thing looks like okay so there's the whole electrode assembly all hooked up now the final thing that i want to make sure of here is to make sure that nothing is shorted i want to make sure that i don't have any wires hitting other wires okay because the short could be devastating to the experiment all right so it doesn't look like i have any shorts here everything seems to be properly connected all right we are indeed on the external mode and we have everything set up over here exactly as we should again three segments our first segment is initially starting at zero volts will scan out to positive point eight volts which should cause oxidation to occur if we have acetaminophen in the solution second segment is from 0. 8 volts back to minus 0. 3 volts that should cause reduction the opposite process to occur as we scan back in the negative direction and then finally back to our original potential of zero volts in our third segment all right so let's go ahead and take a background um voltammogram and see how we've done so i'm going to hit the perform button here we'll stand back a little so we can see the voltammogram develop okay the experiment is in progress and we can actually see current starting to flow here okay so we're moving in an oxidative direction now back in the reductive direction and again this is our buffer solution so there's no acetaminophen in here so we shouldn't see a whole lot of current flowing and indeed we don't so what we get here is actually a very nice textbook background voltammogram so again the voltammogram if you'll notice is going to be a plot of current flowing at the working electrode as a function of the potential that we apply to that working electrode all right so again we notice that there's very little current flowing and that's exactly what we would expect so we've actually chosen a good potential window here to look at the oxidation and reduction of acetaminophen so at this point um you could save this if you like um you could photograph it at this point in the game we've had a look at it so i'm satisfied all right so at this point i'm going to come back to the cell again and now what i'm going to do is i'm going to take the cell apart and replace the buffer solution that i have there see i get my tripod right replace the buffer solution that i have there with a solution that actually contains some acetaminophen all right so i actually have a solution of acetaminophen that i generated from the stock solution that was in the lab and this would be the same solution that you would be using to make up your standards all right so i'm going to now unhook all of the connections from the electrochemical cell i'm going to now pull out the electrode assembly and set it aside and i'm going to pour out the buffer solution so i'm going to pour that right back into the waste container here and now i'm going to come back and take the contents of the volumetric flask which contains the standard acetaminophen solution and pour that into the cell container and you can use as much of it as you wish so you can see if i've used all of it i have my cell container about three quarters of the way full so i'll place the cell container back in the clamp and i can shake off the electrode assembly if i like and i'm going to place the electrode assembly back in the cell container okay now at this point i'm going to remake my connections again the red is the counter electrode so it goes to the platinum wire the black is the working electrode so it's going to come into the carbon disk and then finally we're going to make our last a reference connection here to the reference electrode all right so now the acetophenofen solution is ready to examine so we are now going to come back across here now this point i don't really think i need to make any adjustments we'll run a voltammogram and see how we do so to come back to run a new voltammogram i'm just going to come back to the cv parameters and this is going to restore the very same parameters that i had before so we're going to take a voltammogram and take a look and see how our current range is doing as i said if it turns out that we actually over range the current we can come back and account for that all right so i'm going to hit perform here and let's see what the voltammogram looks like this time with some acetaminophen present in the solution now notice at this point ah current is flowing lots of current is flowing now the current's coming back back down again and we're getting reduction occurring and now we're going to sweep our third segment back now here's the problem you can tell by looking at this voltammogram that we don't have enough current range on our amplifier here in other words we're cutting off the current in both directions so the way i'm going to compensate for this is i'm going to come back to the cv parameters here and i'm going to go back to the k1 range here and i'm going to make it bigger so i'm cutting off at plus or minus 5 microamps so i want to increase that window so let's be good and careful and take that out to 25 microamps and let's see what happens when i run the experiment at this point so we'll go back to perform with that new current range and see how we did so now we've expanded our current range so we should be able to see the whole peak aha there it is up i'm still cutting off a little bit so again you can see there's some trial and error associated with this looks like we got the reductive peak this time though but we still need to back the current off a little bit more the current range make it a little bigger to catch the oxidative peak so again i'm going to come back to my parameters and i'm going to say all right if i didn't catch it in 25 micrograms of range maybe i can catch it in 50 microamps of range so i'm going to double that current range out again now we'll perform see how we do this time i think the solution was a little more concentrated than i thought it was ah looks like we got it that time because the concentration is so high we're getting a little bit of a double peak there but that's okay what we want to be able to do for quantitative purposes is find the largest peak for the oxidation process so again to summarize what we're seeing here we're starting here at zero i'm scanning positively and now this large increase of current as we go positive corresponds to the oxidation of the acetaminophen then i'm going to reverse the scan i'm going to go negatively and now this peak back here corresponds to the reduction of the oxidized species that i generated in the first part of the scan at the electrode surface now the next thing you're going to want to do is to quantitatively obtain a current for that peak so what we're going to do is we're going to left click on the voltammogram and then i'm going to come back with a right click and what i want to do is add a tool here and i want to add a peak height tool so let's click on that now what we're going to see is that we have two pink dots two black dots and a green dot now the green dot corresponds to the peak that we want so what i'm going to do is i'm going to grab the green dot and i'm going to drag it up to the peak of the voltammogram and leave it there so now what ends up happening is we have the two pink dots inside of the two black dots i want to use the pink dots to generate a background here okay so this is going to be a reference point that we're going to use so that we can essentially subtract off any background current that we see and then the primary thing is to make sure that the black dots lie outside of the pink dots so now what we have is a current all the way to the top of the peak that corresponds to 39.